DevExcel, Water, Boiling, Density, Specific enthalpy, Viscosity Sream properties - Physical characteristics of steam of 0 to 30 bar - Density - Specific enthalpy
Dynamic viscosity - Heat capacity - Absolute pressure - Specific heat of steam.
French site
| Home | Thematic | Tables | Programs | Library | Download | Links | Contact | Forum |
_You are in the heading
 
Steam characteristics (from 30 to 100 bar)
TABLES
Mesure units
Fluid mechanic



Absolute pressure: Absolute pressure = Gauge Pressure + Atmospheric pressure (Atmospheric pressure at 1,01325 bar, i.e. normal atmospheric pressure on the sea level at 0°C).
Boiling point: Temperature of saturated vapour or also of ebullient water under the same pressure.
Specific volume of steam: Volume occupied in m3 by 1 kg of steam
Mass density (or Density) of the steam: Specific mass of the steam in a volume of 1 m3
Specific enthalpy
of liquid water:
Sensible Heat, it is the quantity of heat contained in 1 kg of water according to the selected temperature.
Specific enthalpy of the steam: It is the total heat contained in 1 kg of steam. It is the sum of the enthalpy of the various states, liquid (water) and gas (vapour)
Latent heat of vaporization:
Heat necessary to transform 1 kg of ebullient water into vapour without change of temperature (thermal energy necessary during the change of state liquid to the state vapour)

Specific heat of steam:

Quantity of heat necessary to increase the temperature of one Celsius degree on a unit of mass of 1 kg of steam.
Dynamic viscosity: The viscosity of a fluid characterizes the resistance to the movement of the fluid.
NB: Energy values in kcal/kg are given on a basis of 4.1868 J, values not normally used.

Absolute
pressure
Boiling point
Specific volume (steam)
Density (steam)
Specific enthalpy
of liquid water (sensible heat)
Specific enthalpy of steam
(total heat)
Latent heat of vaporization
Specific heat
Dynamic viscosity
bar
°C
m3/kg
kg/m3
kj/kg
Kcal/kg
kj/kg
Kcal/kg
kj/kg
Kcal/kg
kj/kg
kg/m.s
30
233.84
0.067
15.009
1008.33
240.84
2802.27
669.31
1793.94
428.48
3.4069
0.000017
31
235.66
0.064
15.512
1016.97
242.90
2802.33
669.32
1785.36
426.43
3.4442
0.000017
32
237.44
0.062
16.016
1025.41
244.92
2802.32
669.32
1776.90
424.41
3.4815
0.000017
33
239.18
0.061
16.521
1033.69
246.89
2802.25
669.31
1768.56
422.41
3.5187
0.000017
34
240.88
0.059
17.028
1041.79
248.83
2802.12
669.28
1760.33
420.45
3.5559
0.000017
35
242.54
0.057
17.536
1049.74
250.73
2801.95
669.23
1752.20
418.51
3.5932
0.000017
36
244.16
0.055
18.046
1057.54
252.59
2801.72
669.18
1744.17
416.59
3.6305
0.000017
37
245.75
0.054
18.557
1065.21
254.42
2801.44
669.11
1736.24
414.69
3.6679
0.000017
38
247.31
0.052
19.070
1072.73
256.22
2801.12
669.04
1728.39
412.82
3.7054
0.000017
39
248.84
0.051
19.585
1080.13
257.98
2800.75
668.95
1720.62
410.96
3.7429
0.000018
40
250.33
0.050
20.101
1087.40
259.72
2800.34
668.85
1712.94
409.13
3.7806
0.000018
41
251.80
0.048
20.619
1094.56
261.43
2799.89
668.74
1705.33
407.31
3.8185
0.000018
42
253.24
0.047
21.138
1101.61
263.12
2799.40
668.62
1697.79
405.51
3.8565
0.000018
43
254.66
0.046
21.660
1108.55
264.77
2798.87
668.50
1690.32
403.73
3.8946
0.000018
44
256.05
0.045
22.183
1115.39
266.41
2798.30
668.36
1682.91
401.96
3.9329
0.000018
45
257.41
0.044
22.708
1122.13
268.02
2797.70
668.22
1675.57
400.20
3.9715
0.000018
46
258.76
0.043
23.235
1128.78
269.60
2797.07
668.07
1668.29
398.46
4.0102
0.000018
47
260.08
0.042
23.763
1135.33
271.17
2796.40
667.91
1661.06
396.74
4.0492
0.000018
48
261.38
0.041
24.294
1141.80
272.71
2795.69
667.74
1653.89
395.03
4.0884
0.000018
49
262.66
0.040
24.827
1148.19
274.24
2794.96
667.57
1646.77
393.32
4.1279
0.000018
50
263.92
0.039
25.362
1154.50
275.75
2794.20
667.38
1639.70
391.64
4.1676
0.000018
51
265.16
0.039
25.898
1160.73
277.23
2793.41
667.19
1632.68
389.96
4.2076
0.000018
52
266.38
0.038
26.437
1166.88
278.70
2792.58
667.00
1625.70
388.29
4.2479
0.000018
53
267.58
0.037
26.978
1172.97
280.16
2791.74
666.79
1618.77
386.64
4.2885
0.000018
54
268.77
0.036
27.521
1178.98
281.59
2790.86
666.59
1611.88
384.99
4.3294
0.000018
55
269.94
0.036
28.067
1184.93
283.02
2789.95
666.37
1605.03
383.35
4.3706
0.000018
56
271.09
0.035
28.614
1190.81
284.42
2789.02
666.15
1598.21
381.73
4.4122
0.000018
57
272.23
0.034
29.164
1196.64
285.81
2788.07
665.92
1591.43
380.11
4.4541
0.000018
58
273.36
0.034
29.716
1202.40
287.19
2787.09
665.68
1584.69
378.50
4.4963
0.000019
59
274.47
0.033
30.270
1208.10
288.55
2786.08
665.44
1577.98
376.89
4.5389
0.000019
60
275.56
0.032
30.827
1213.75
289.90
2785.05
665.20
1571.31
375.30
4.5819
0.000019
61
276.64
0.032
31.386
1219.34
291.23
2784.00
664.95
1564.66
373.71
4.6253
0.000019
62
277.71
0.031
31.947
1224.88
292.56
2782.92
664.69
1558.04
372.13
4.6691
0.000019
63
278.76
0.031
32.511
1230.37
293.87
2781.82
664.43
1551.45
370.56
4.7133
0.000019
64
279.80
0.030
33.077
1235.81
295.17
2780.70
664.16
1544.89
368.99
4.7578
0.000019
65
280.83
0.030
33.646
1241.20
296.45
2779.55
663.89
1538.36
367.43
4.8029
0.000019
66
281.85
0.029
34.218
1246.54
297.73
2778.39
663.61
1531.85
365.88
4.8483
0.000019
67
282.85
0.029
34.792
1251.84
299.00
2777.20
663.32
1525.36
364.33
4.8943
0.000019
68
283.85
0.028
35.368
1257.09
300.25
2775.99
663.03
1518.90
362.78
4.9407
0.000019
69
284.83
0.028
35.948
1262.31
301.50
2774.76
662.74
1512.45
361.24
4.9875
0.000019
70
285.80
0.027
36.529
1267.48
302.73
2773.51
662.44
1506.03
359.71
5.0348
0.000019
71
286.76
0.027
37.114
1272.61
303.96
2772.24
662.14
1499.63
358.18
5.0827
0.000019
72
287.71
0.027
37.702
1277.70
305.17
2770.95
661.83
1493.25
356.66
5.1310
0.000019
73
288.65
0.026
38.292
1282.75
306.38
2769.64
661.52
1486.89
355.14
5.1798
0.000019
74
289.59
0.026
38.885
1287.77
307.58
2768.31
661.20
1480.54
353.62
5.2292
0.000019
75
290.51
0.025
39.481
1292.75
308.77
2766.97
660.88
1474.21
352.11
5.2791
0.000019
76
291.42
0.025
40.080
1297.70
309.95
2765.60
660.55
1467.90
350.60
5.3295
0.000019
77
292.32
0.025
40.681
1302.61
311.12
2764.22
660.22
1461.61
349.10
5.3805
0.000019
78
293.22
0.024
41.286
1307.49
312.29
2762.81
659.89
1455.32
347.60
5.4321
0.000019
79
294.10
0.024
41.894
1312.34
313.45
2761.39
659.55
1449.06
346.10
5.4843
0.000019
80
294.98
0.024
42.505
1317.15
314.60
2759.95
659.20
1442.80
344.61
5.5370
0.000019
81
295.85
0.023
43.118
1321.94
315.74
2758.50
658.86
1436.56
343.12
5.5904
0.000020
82
296.71
0.023
43.735
1326.70
316.88
2757.03
658.50
1430.33
341.63
5.6443
0.000020
83
297.56
0.023
44.356
1331.42
318.01
2755.54
658.15
1424.11
340.14
5.6989
0.000020
84
298.40
0.022
44.979
1336.12
319.13
2754.03
657.79
1417.91
338.66
5.7542
0.000020
85
299.24
0.022
45.606
1340.79
320.24
2752.50
657.42
1411.71
337.18
5.8101
0.000020
86
300.07
0.022
46.235
1345.44
321.35
2750.97
657.06
1405.52
335.70
5.8666
0.000020
87
300.89
0.021
46.869
1350.06
322.46
2749.41
656.68
1399.35
334.23
5.9239
0.000020
88
301.71
0.021
47.505
1354.66
323.55
2747.84
656.31
1393.18
332.76
5.9818
0.000020
89
302.51
0.021
48.146
1359.22
324.65
2746.25
655.93
1387.02
331.28
6.0404
0.000020
90
303.31
0.020
48.789
1363.77
325.73
2744.64
655.55
1380.87
329.82
6.0998
0.000020
91
304.11
0.020
49.436
1368.29
326.81
2743.02
655.16
1374.73
328.35
6.1599
0.000020
92
304.89
0.020
50.087
1372.80
327.89
2741.39
654.77
1368.59
326.88
6.2208
0.000020
93
305.67
0.020
50.741
1377.27
328.96
2739.73
654.37
1362.46
325.42
6.2825
0.000020
94
306.45
0.019
51.399
1381.73
330.02
2738.07
653.98
1356.34
323.96
6.3450
0.000020
95
307.22
0.019
52.061
1386.17
331.08
2736.38
653.57
1350.22
322.49
6.4083
0.000020
96
307.98
0.019
52.726
1390.58
332.13
2734.69
653.17
1344.11
321.03
6.4725
0.000020
97
308.73
0.019
53.396
1394.98
333.18
2732.98
652.76
1338.00
319.57
6.5376
0.000020
98
309.48
0.018
54.069
1399.35
334.23
2731.24
652.35
1331.89
318.12
6.6036
0.000020
99
310.22
0.018
54.746
1403.71
335.27
2729.50
651.93
1325.79
316.66
6.6705
0.000020
100
310.96
0.018
55.427
1408.05
336.31
2727.74
651.51
1319.69
315.20
6.7385